Learn in this tutorial how to manage delayed automatic closure |
In order for the automatic closure MODE to be used, it is imperative to have plugged photocells into the electronic board.
Press the "ProG" key on the card for 3 seconds (L1 lights up).
Press "+" 3 times (L4 lights up).
Press "SET" once (by default, L1 is on).
Press "+" once (L1 and L2 light up).
Press "SET" once (all lights come on and then off).
If L1 stays on after animating the red lights, then activating the automatic closure failed.
Check the correct connection of the photocells.
By default, the waiting time for the card before automatically starting closing is 30s.
If you want to change the wait time, refer to the tutorial "Setting Time" tutorial.