How to recognize generations for TEHA and STYRKA engines

How to recognize generations for TEHA and STYRKA engines

Comment reconnaitre les générations pour les mo...

The engines of the TEHA (410 and Connect) range as well as the STYRKA 310 engine have existed over two different generations.Electronic cards and electric motors are different and must be adapted to the version.We will detail in this tutorial how to accurately identify which version your engine is.


Difficulty: Easy
Time required: 2 minutes
Number of steps: 2
Updated: October 2025
Detached part(s):
Reference: 580041FAvlo piston carte
Reference: 580041FAStyrka v2 electronic carte
Reference: 580041GTeha electronic carte
Reference: 580041GAElectronic carte v2
Reference: 581156AElectric motor teha v1
Methode 1 Identification visuelle du moteur éle...

Method 1: Visual identification of electric motor

To quickly access the electric motor and to be able to control its version follow the steps below

Enlever les caoutchoucs

Remove rubbers

Using a clamp or a small flat screwdriver, remove the 4 rubber protections on the rear fork of the engine.


Enlever les vis de fixation

Remove fixing screws

Using a BTR tool (4mm), unscrew and remove the 4 screws for holding the rear fork on the engine.


Identification visuelle V1

Visual identification V1

Lightly pivot the fork, and observe the rear face of the electric motor.

If the electric motor connection wires leave the engine directly, this will be the V1 (see photo)

Identification visuelle V2

Visual identification V2

Lightly pivot the fork, and observe the rear face of the electric motor.

If the connecting wires of the electric motor are on connection pads, it will be the V2 (see photo)

Methode 2 Voyant sur la carte

Method 2: Seeing on the map

It is possible to know the version of the electronic card by performing a manipulation during its electrical start.

Mettre la carte hors tension

Turn off the card

Unplug your transformer from the card (blue eyelashes with the white connector), and wait until it turns off completely


Demander à la carte sa version de logiciel

Ask the map for its software version

While holding down OK key, reconnect the transformer on the card.


Regarder les voyants

Watching the seers

The card will then display a red light.

Refer to the table below to find out if the engine is 1st or 2nd generation.

Redémarrer la carte

Restart the map

For the card to regain its standard condition, unplug the card transformer again (blue wire with the white connector). Patient a few seconds, then restart the card without touching the buttons.


Version 2 exclusives

Exclusive Version 2

The commercial references of the engines listed below have only one generation and are exclusively in V2

  • 114176
  • 114300
  • 114301
  • 114303
  • 114304
  • 114307