Find out in this tutorial how to manage timed automatic closure |
In order for the automatic MODE to be used, it is imperative to have plugged photocells to the electronic card.
Press the "PROG" button on the card for 3 seconds (L1 turns on).
Press "+" 3 times (L4 turns on).
Press "SET" once (default, L1 is on).
Press "+" once (L1 and L2 turn on).
Press "SET" once (all lights turn on and then turn off).
If L1 remains on after animating the red lights, then activation of the automatic closing failed.
Check the correct connection of the photocells.
By default, the card waiting time before automatically starting closing is 30s.
If you want to change the waiting time, refer to the "Time Time Setting" tutorial.