We will see in this tutorial how to connect photocells to an electronic card AVLO |
The tutorial below will represent a connection with the current photocells 114359 oval.
The old photocells 104359 (Extel), or 114359 rectangular photocells will be compatible with an AVLO electronic card.
The connection will be identical with the exception of photocells 104359.
Remove the shunt betweenGndandPhoelectronic card.
Connect the+24Vphotocells on the+24Vof the card.
Connect theGndphotocells on theGndof the card.
Connect theNcof the RX photocell onPhoof the card.
Put a shunt betweenGndandComreceiving photocell.
Remove the shunt betweenGndandPhoelectronic card.
Connect the+photocells on the+24Vof the card.
Connect the-photocells on theGndof the card.
Connect theNcof the RX photocell onPhoof the card.
Put a shunt between-andComreceiving photocell.