In case of non-operating an intercom, we recommend performing a short-distance functional test.The purpose of this test is to ensure that your malfunction is not related to a failure of your installation (cut, cut or damaged cable).
Difficulty: Easy
Time required: 10 minutes
Number of steps: 5
Updated: September 2024
Step 1: Turn off your device
Unplug your AC adapter before intervening on the device.
or
Lower the circuit breaker associated with your device.
Step 2: Disassembly of your Street Panel
Remove the front from your door station.
Then remove the two screws that hold your door station on its support.
Gently remove your door station from its wall mount.
Disconnect the two wires connecting the terminals 1 and 2 of the monitor to the terminals 1 and 2 of the door station.(Also disconnect terminals 3,4 and 5.6 if you have an electric trigger and gate)
Bring your door station close to your interior monitor.
Step 3: Monitor Disassembly
Remove the monitor from its support by lifting it up and gently return it.
Disconnect the wires present on terminals 1/3 and 2/4.
Step 4: Short distance connection
Equip yourself with a 2m cable and section 1.5mm2 then connect the 1/3 of the monitor terminal to terminal 1 of the door station (red thread on the diagram).
Equip yourself with a 2m cable and section 1.5mm2 then connect the monitor terminal 2/4 of the door station (blue thread on the diagram).
Step 5: Energizing and functional test
Connect your AC adapter to 230V
or
Remove the circuit breaker associated with your device.
Make sure the product works properly.
In the case where your malfunction is identical, please contact the technical support.
In the case of correct operation of the intercom, please check your installation.