Perform a short test with a Philips video doorman

Perform a short test with a Philips video doorman

Réaliser un test court avec un portier vidéo Ph...

In case of non-operating an intercom, we recommend performing a short-distance functional test.The purpose of this test is to ensure that your malfunction is not related to a failure of your installation (cut, cut or damaged cable).

Difficulty: Easy
Time required: 10 minutes
Number of steps: 5
Updated: September 2024

Step 1: Turn off your device

  • Unplug your AC adapter before intervening on the device.

or

  • Lower the circuit breaker associated with your device.

Step 2: Disassembly of your Street Panel

  • Remove the front from your door station.
  • Then remove the two screws that hold your door station on its support.
  • Gently remove your door station from its wall mount.
  • Disconnect the two wires connecting the terminals 1 and 2 of the monitor to the terminals 1 and 2 of the door station.(Also disconnect terminals 3,4 and 5.6 if you have an electric trigger and gate)
  • Bring your door station close to your interior monitor.

Step 3: Monitor Disassembly

  • Remove the monitor from its support by lifting it up and gently return it.
  • Disconnect the wires present on terminals 1/3 and 2/4.

Step 4: Short distance connection

  • Equip yourself with a 2m cable and section 1.5mm2 then connect the 1/3 of the monitor terminal to terminal 1 of the door station (red thread on the diagram).
  • Equip yourself with a 2m cable and section 1.5mm2 then connect the monitor terminal 2/4 of the door station (blue thread on the diagram).

Step 5: Energizing and functional test

  • Connect your AC adapter to 230V

or

  • Remove the circuit breaker associated with your device.

  • Make sure the product works properly.
  • In the case where your malfunction is identical, please contact the technical support.
  • In the case of correct operation of the intercom, please check your installation.