Problème de production

Production problem

  • In case of a production problem, please control the performance of your inverter from the application:
  • On the home page of the SORIA kit, press "Device Information"
  • The value "V" corresponds to the voltage supplied by your solar panels.With 2 compliant solar panels, you should have a value greater than 35V
  • The value "Political Current" value corresponds to the intensity produced by your solar panels.This value will depend on the positioning of your solar panels as well as the light power of the sun.Good exposure should be around 9A.

Example with a poorly connected or faulty solar panel

  • Incorrect photovolta voltage
  • Correct Photovoltaic current

Incorrect or low light intensity exposure

  • Correct Photovoltaic voltage
  • Incorrect photovolta current

This is the most common case, it depends on the light power of the sun, its temperature, its exposure...

It is normal to have these values in autumn as well as winter.

Check the exposure of solar panels

the micro-onduleer has a maximum yield of 92.7%.

Electricity generation depends on:

  • The orientation of the panels: make sure that the 2 panels are facing south.
  • Panel temperature: too high or too low a temperature will put the inverter safe and limit its performance
  • The presence of shadow or not on the panels: a shaded part even minimal on the panels will cause a drop in performance
  • Inclination: It is imperative to use the supports provided in order to respect a 30° inclination
  • The efficiency of the inverter: The 400W of the solar kit are the maximum peak production of the panels. Since the inverter has a maximum yield of 92.7%, effective production will be lower.

L'onduleur ne fournit pas de courant

The inverter does not provide current

  • Please check the tutorial " Meaning of the inverter" tutorial
  • The inverter must be calibrated to the power grid in order to produce current. If the light is flashing red, it means that the inverter is not connected to the 230V or that there is no current in the socket.
  • If these parameters are correct, the inverter encounters a malfunction.
Le kit SORIA fait sauter le disjoncteur

The SORIA kit makes the circuit breaker

  • Ensure the proper compliance of your electrical installation. Unplug the SORIA kit from your power outlet and rearm the circuit breaker.
  • If the circuit breaker does not trigger, the inverter is faulty
  • Make sure the inverter is not exposed outside the solar panel
Impossible de le connecter en Wifi

Cannot connect it in Wifi

  • Make sure the inverter is in the action field of your internet box.
  • The antenna is integrated into the inverter and the latter being on the ground, it will have less radio range than a smartphone. Position the latter at the exact location of the inverter to see its Wifi reception
  • Make sure that at the location of the solar panel, you pick up at least 2 Wi-Fi reception bars on your smartphone.
  • The inverter is compatible with a 2.4Ghz WiFi network only.