Problème de production

Production problem

  • In case of a production problem, please control the performance of your inverter from the application:
  • Press "PV Power"

  • The value "Potor voltage" corresponds to the voltage supplied by your solar panels.With 4 compliant solar panels and in full sun, you should have a value of 34V
  • The value "Political Current" value corresponds to the intensity produced by your solar panels.This Value will depend on the positioning of your solar panels as well as the light power of the sun.Good exposure should be around 10A.

Example with a poorly connected or faulty solar panel

  • Photovoltaic voltage is incorrect
  • Photovoltaic current is correct

Incorrect exposure or low light intensity

  • Photovoltaic voltage is correct
  • Photovoltaic current is incorrect

This is the most common case, it depends on the light power of the sun, its temperature, its exposure

It is normal to have these values in autumn as well as winter.

Check the exposure of solar panels

the micro-onduler has a maximum yield of 92.7%.

Electricity generation depends on:

  • The orientation of the panels: make sure that the 4 panels are facing south.
  • Panel temperature: too high or too low a temperature will safely put the inverter and limit its performance
  • The presence of shadow or not on the panels: a shaded part even minimal on the panels will cause a drop in performance
  • Inclination: It is imperative to use the supports provided in order to respect a 30° inclination
  • The efficiency of the inverter: The 400W of the solar kit is the maximum peak production of the panels. Since the inverter has a maximum yield of 92.7%, effective production will be lower.

L'onduleur ne fournit pas de courant

The inverter does not provide current

  • Please check the tutorial " Meaning of the inverter" tutorial
  • The inverter must be calibrated to the power grid in order to produce current. If the light is fixed red, this means that the inverter is not connected to the 230V or that there is no current in the socket.
  • If these parameters are correct, the inverter encounters a malfunction.
Le kit SORIA fait sauter le disjoncteur

The SORIA kit makes the circuit breaker

  • Ensure the proper compliance of your electrical installation. Unplug the SORIA kit from your power outlet and rearm the circuit breaker.
  • If the circuit breaker does not trigger, the inverter fails
  • Make sure the inverter is not exposed outside the solar panel
Impossible de le connecter en Wifi

Cannot connect it in Wifi

  • Make sure the inverter is in the action field of your internet box.
  • The inverter is compatible with a 2.4Ghz WiFi network only.
  • Make sure the antenna is properly positioned on the inverter
  • The antenna must be installed by hand and should not be blocked or tightened at the key.
  • If the antenna rotates in a vacuum, the inverter fails.