You can adjust more accurately and adjust it according to your environment. |
01: Calibration of the temperature probe:Permetting the temperature displayed on the probe if this does not match the reality
02: Maximum set temperature:Allows you to limit the maximum set temperature
03: Minimum set temperature:Allows you to limit the minimum set temperature
05: Non-frost temperature:Allows you to adjust the temperature out of frost
09: Dead area:Avoids activating air conditioning and heating simultaneously. 0 = unlocked / 1= locked
10: Default display:Allows you to display the set temperature when the thermostat is on standby = 1 or room temperature = 0
11: Locking of keys:Allows you to lock thermostat buttons = 1 or unlock = 0
12: Automatic window detection.Enables window detection mode = 1 or disable = 0
13: Window opening detection time:Allows you to set the detection time when opening a window (in min)
14: Sensitivity of temperature drop window:Allows you to adjust the detection sensitivity when a window is open (in °C)
15: Cut-off time heating after window opening:Allows you to adjust the time (in min) when the heating will be cut following a window opening.
17: Reset:Allows you to reset thermostat adjustment = 1 and then press the center button for 5 seconds