Perform a short test with an Avidsen video doorman

Perform a short test with an Avidsen video doorman

Réaliser un test court avec un portier vidéo Av...

In case of non-operating an intercom, we recommend performing a short-distance functional test.The purpose of this test is to ensure that your malfunction is not related to a failure of your installation (cut, cut or damaged cable).

Difficulty: Easy
Time required: 10 minutes
Number of steps: 5
Updated: October 2024

Step 1: Turn off your device

  • Unplug your AC adapter before intervening on the device.

or

  • Lower the circuit breaker associated with your device.

Step 2: Disassembly of your Door station

  • Remove the door station from its wall mount by removing the safety screw under the door station.
  • Declips the connection terminal block.
  • Disconnect the two wires connecting the terminals 1 and 2 of the monitor to the terminals 1 and 2 of the door station. (Also disconnect terminals 3,4 and 5.6 if you have an electric trigger and gate)
  • Bring your door station close to your interior monitor.

Step 3: Unassembly of the Monitor

  • Remove the monitor from its support by lifting it up and gently return it.
  • Disconnect the wires present on terminals 1 and 2.

Step 4: Short distance connection

  • Equip yourself with a 2m cable and section 1.5mm2 then connect the monitor terminal 1 of the door station (red wire on the diagram).
  • Equipped with a 2m cable and section 1.5mm2 then connect the monitor terminal 2 of the monitor to terminal 2 of the door station (blue wire on the diagram).

Attention: the connection terminal of the door station makes sense.It is imperative to respect the meaning under penalty of malfunction (untimely calls, call button not working, etc.)

Step 5: Energizer and functional test

  • Connect your AC adapter to 230V

or

  • Remove the circuit breaker associated with your device.

  • Make sure the product works properly.
  • In the case where your malfunction is identical, please contact the technical support.
  • In the case of correct operation of the intercom, please check your installation.